Equipment at work, film material and can not easily offset the normal feeding how to adjust?

A: In the device in case of film material deviation, adjusted the position and tension roll stabilizer bars are not valid cases, by adjusting the angle of the triangle to solve this problem. Expected to deviate from the folder, such as the upper membrane material chain can be adjusted on the triangle to the clockwise direction; are expected to deviate from the folder-layer membrane material chain can be adjusted on the triangle to the counter-clockwise.

Q: shrinking machine is slow or unable to rise to the higher heating temperature (160 degrees Celsius or above) What are the reasons?

A: The heater circuit is the main power line through a magnetic switch and then to electric suction pipe, it should be the first detection of smoke magnetic switch contacts are normal. If line does not pass one of the phase, the above phenomenon occurs. If the normal suction magnetic switch can be re-check the meter to see if the phase and the ohmic value of the machine are the same. If you normally should be short. If each phase are connected to electric wires or tubes, but is still an exception, it would take to replace heater.

Q: The cluster package 6 bottle packaging, electric eye can not detect the packaging, machine work, easy to cut to the packaging, should be how to adjust?

A: The cluster package will affect the margins of each bottle electric eye to detect, when the level of electric eye can be detected as a bevel angle adjustment. Adjustment can reduce the electric eye to detect the risk of packaging space and thus avoid the phenomenon of emerging programs indiscriminately.